Q-ADEPT HPLC SYSTEM Q-2, Binary - Low Pressure Gradient

This is the ideal system for sophisticated method development. The system offers power and flexibility and yet is compact and convenient to use.


The CE 4104 Quaternary pump is provided for low pressure mixing of up to 4 solvents. A dynamic mixer, built into the pump, provides excellent solvent mixing for reproducible gradients.


The Adept CE 4300 WaveQuest DAD fast scanning detector is supplied with an 8µL x 10mm flowcell and fitted with a mounting panel for the Rheodyne injection valve.


Purity, compound identification, match factors using library search and virtually drift free monitoring may be carried out using this excellent system on the same scan as peaks are quantified cutting experimental time in half.


The PowerStream system controller is mounted at the centre of the stack and full control and data Processing are provided for use in Windows. A solvent and pipe organiser, CE 4134 and installation kit 4150 14 00 are provided.


The system is completed by the CE 4600 heated and cooled oven, which accommodates up to three columns


This is a low pressure binary gradient forming system. It uses the CE 4102 dual piston pump with flow rates from 0.001 to 10mL/min and a maximum operating pressure of 40MPa.


The pump has the facility for mixing two solvents for binary gradients and of course may be used in the isocratic mode.


The Adept CE 4200 dual wavelength detector is used with an 8µL x 10mm flowcell. The Rheodyne valve fitted with a 20µL loop is mounted with the column on the mounting panel CE 4050.


The PowerStream software controller is mounted at the centre of the stack. Full control and data processing are provided for use with Windows.


A Solvent Reservoir and Pipe Organiser and installation kit are also supplied.

This extremely popular quaternary low pressure gradient system is shown here with a Cecil column heater/chiller, which should be ordered extra if required. The CE 4104 dual piston pump has flow rates from 0.001 to 10µL/min and a maximum operating pressure of 40MPa. The pump has all the facilities for gradient formation, with low pressure mixing of up to 4 solvents.


Four, proprietary, high performance, high reliability, proportioning valves are used to control up to four solvents and a high performance, low volume, dynamic mixer is used for ultimate gradient quality.


The Adept CE 4200 dual wavelength detector is used with an 8µL x 10mm flowcell. The Rheodyne valve with 20µL loop is mounted by a small panel to the detector. When an oven is not used the column may be mounted together with the valve on mounting panel CE 4050.

 

The CE 4900 PowerStream system controller is placed at the centre of the very compact stack. Full control and data processing ar provided for use in Windows. The system is supplied complete with solvent and pipe organiser, CE 4134, 8µL x 10mm flowcell and installation kit 4150 14 00.

Q-ADEPT HPLC SYSTEM Q-4, Quaternary - Low Pressure Gradient

Q-ADEPT HPLC SYSTEM Q-4S, Method Development

This automatic version of system Q-4 is shown.


The system is the same as system Q-4, but the injection valve is supplied as part of the AutoQuest autosampler to which it is fitted. Installation kit 4150 14 01 is supplied.

Q-ADEPT HPLC SYSTEM Q-6,

Automatic Quaternary - Low Pressure Mixing Gradient

A Cecil HPLC system acquired chromatogram, of a spiked honey sample, during the analysis of Hydroxymethylfurfural (HMF) in honeys.

DataStream software Specifications AutoQuest Autosampler Pumps PowerStream software Components Detectors Overview Selecting systems Ordering systems

Low Pressure Gradient Mixing